Description
Pro Max 150AH 12V Tubular Battery, designed for reliable power storage with a robust design, long-lasting performance, and efficient energy output.
Technical Specifications
| Model | FR-2204 |
|---|---|
| Voltage | 12V |
| Capacity | 150Ah |
| Dimensions (L x W x H x OH) | 502 x 191 x 397 x 415 mm |
| Battery Weight | 54.0 Kg |
| Battery packed weight | 56.5 Kg |
| Capacity (Duration) | 195~225 Min @ 400W |
|---|---|
| 20Hr Capacity | 150 Ah |
| 10Hr Capacity | 126 Ah |
| 5Hr Capacity | 105 Ah |
| Internal Resistance | 9.0 mΩ |
Charging Instructions
| Boost Charging (Starting Rate) | 15.1 A |
|---|---|
| Boost Charging (Finishing Rate) | 7.6 A |
| Trickle Mode Charging (Minimum) | 126 mA |
| Trickle Mode Charging (Maximum) | 504 mA |
Constant Power Discharge Performance
| 500W Backup Duration | 02:40 |
|---|---|
| 400W Backup Duration | 03:30 |
| 300W Backup Duration | 04:30 |
| 200W Backup Duration | 07:30 |
| 100W Backup Duration | 16:00 |
Charge Characteristics (27°C)
| Cycle Use | 14.40 â 15.0V (-40mV/°C), Maximum Current 22.5A |
|---|---|
| Standby Use | 13.60 – 13.80V (-20mV/°C) |
Charge Temperature Compensation
| Add | 0.005 Volt per cell for every 1°C below 25°C 0.0028 Volt per cell for every 1°F below 77°F |
|---|---|
| Subtract | 0.005 Volt per cell for every 1°C above 25°C 0.0028 Volt per cell for every 1°F above 77°F |
Operational Data
| Operating Temperature | -4°F to 113°F (-20°C to +45°C). At temperatures below 32°F (0°C) maintain a state of charge greater than 60%. |
|---|---|
| Self Discharge | Less than 3% per month at 20°C temperature conditions. |
| Rated Capacity at Ambient Temperature | As per formula: Ct=C27{1+0.0043(t-27)} |
| Self-Discharge Standard | Conforms to IS13369-1992 |